Sign In | Join Free | My burrillandco.com
Home > Pressure Temperature Transmitter >

3051TG5F2A21AB4 Rosemount 3051t Pressure Transmitter In Line New In Box

Wisdomlong Technology CO.,LTD
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap 3051TG5F2A21AB4 Rosemount 3051t Pressure Transmitter In Line New In Box from wholesalers
     
    Buy cheap 3051TG5F2A21AB4 Rosemount 3051t Pressure Transmitter In Line New In Box from wholesalers
    • Buy cheap 3051TG5F2A21AB4 Rosemount 3051t Pressure Transmitter In Line New In Box from wholesalers
    • Buy cheap 3051TG5F2A21AB4 Rosemount 3051t Pressure Transmitter In Line New In Box from wholesalers

    3051TG5F2A21AB4 Rosemount 3051t Pressure Transmitter In Line New In Box

    Ask Lasest Price
    Brand Name : ROSEMOUNT
    Model Number : 3051TG5F2A21AB4
    Price : Negotiate
    Payment Terms : T/T,PAYONEER
    Supply Ability : 20EA,8weeks
    Delivery Time : 8 WEEKS
    Certification : Does not supply
    • Product Details
    • Company Profile

    3051TG5F2A21AB4 Rosemount 3051t Pressure Transmitter In Line New In Box

    3051TG5F2A21AB4 In-Line Pressure Transmitter Rosemount 3051T


    Product Information Of : 3051TG5F2A21AB4

    BrandEMERSON ROSEMOUNT
    Model3051TG5F2A21AB4
    SUPPLY

    Does not supply

    SIZENo
    Weight5KG

    (1) 3051TG lower range limit varies with atmospheric pressure.
    (2) Materials of Construction comply with recommendations per NACE MR0175/ISO 15156 for sour oil field production apply to certain materials. Consult latest standard for details. Selected materials also conform to NACE MR0103
    (3) Not available with low-power Option Code M.
    (4) Not available with fieldbus (output code F) or Profibus protocols (output code W).
    (5) Local zero and span adjustments are standard unless Option Code J1 or J3 is specified.
    (6) NAMUR-Compliant operation is pre-set at the factory and cannot be changed to standard operation in the field.
    (7) The V5 option is not needed with T1 option; external ground screw assembly is included with the T1 option.


    More options:

    SGDA-02AS

    SGDA-02ASP

    SGDA-02BP

    SGDA-02BS

    SGDA-02VP

    SGDA-03BP

    SGDA-03BP+SGMP-03B312

    SGDA-03BPY122

    SGDA-03SP

    SGDA-04AH

    SGDA-04AP

    SGDA-04APP

    SGDA-04AS

    SGDA-04AS+电机SGM-04A3NT12

    SGDA-04ASP


    MR-J2S-200A-S007

    MR-J2S-200B-S009V613

    MR-J2S-200B-RS238

    MR-J2S-200B-S126

    MR-J2S-200A-EG011

    MR-J2S-200A-EG055

    MR-J2S-350B-S041703

    MR-J2S-350CP-S186

    MR-J2S-350CP-S084

    MR-J2S-350B-EG


    Rosemount 3051T In-Line Pressure Transmitter​ Information :

    ModelTransmitter type
    3051TIn-line pressure transmitter
    Pressure type
    GGage
    A(1)Absolute
    Pressure range
    Gage (Rosemount 3051TG)(2)Absolute (Rosemount 3051TA)
    1–14.7 to 30 psi (–1,01 to 2,06 bar)0 to 30 psia (0 to 2,06 bar)
    2–14.7 to 150 psi (–1,01 to 10,34 bar)0 to 150 psia (0 to 10,34 bar)
    3–14.7 to 800 psi (–1,01 to 55,15 bar)0 to 800 psia (0 to 55,15 bar)
    4–14.7 to 4000 psi (–1,01 to 275,79 bar)0 to 4000 psia (0 to 275,79 bar)
    5–14.7 to 10000 psi (–1,01 to 689,47 bar)0 to 10000 psia (0 to 689,47 bar)
    6(3)–14.7 to 20000 psi (–1,01 to 1378,95 bar)0 to 20000 psia (0 to 1378,95 bar)
    Transmitter output
    A(4)4–20 mA with digital signal based on HART® Protocol
    FFOUNDATION™ Fieldbus Protocol
    W(5)PROFIBUS® PA Protocol
    X(6)Wireless (requires wireless options and engineered polymer housing)
    M(7)Low-power 1–5 Vdc with digital signal based on HART Protocol
    Process connection style
    2B½–14 NPT female (range 1–5 only)
    2C(8)G½ A EN837-1 male (range 1–4 only)
    2F(9)Coned and threaded, compatible with autoclave Type F-250-C (range 5–6 only)
    61(10)(11)Non-threaded Instrument flange (range 1–4 only)
    Isolating diaphragm(12)Process connection wetted parts material
    2316L SST316L SST
    3Alloy C-276Alloy C-276
    7Gold-plated 316 SST316L SST
    Sensor fill fluid
    1Silicone
    2(10)Inert
    Housing materialConduit entry size
    AAluminum½–14 NPT
    BAluminumM20 x 1.5
    EAluminum, ultra low copper½–14 NPT
    FAluminum, ultra low copperM20 x 1.5
    JSST½–14 NPT
    KSSTM20 x 1.5
    P(13)Engineered polymerNo conduit entries
    D(14)Aluminum
    M(14)SST
    Wireless options (requires wireless output code X and engineered polymer housing code P)
    Wireless transmit rate, operating frequency, and protocol
    WA3User configurable transmit rate, 2.4GHz WirelessHART
    Antenna and SmartPower
    WP5Internal antenna, compatible with Green Power Module (I.S. Power Module sold separately)
    Options (include with selected model number)
    Extended product warranty
    WR33-year limited warranty
    WR55-year limited warranty
    Plantweb control functionality
    A01FOUNDATION Fieldbus control function block suite
    Plantweb diagnostic functionality
    DA0Loop Integrity HART diagnostic
    D01FOUNDATION Fieldbus diagnostics suite
    Integral assembly(15)
    S5Assemble to Rosemount 306 integral manifold
    Diaphragm seal assemblies(15)
    S1Assemble to one Rosemount 1199 seal
    Mounting bracket(16)
    B4Bracket for 2-in. pipe or panel mounting, all SST
    Product certifications
    E8ATEX Flameproof and Dust Certification
    I1(17)ATEX Intrinsic Safety and Dust
    IAATEX Intrinsic Safety for FISCO; for FOUNDATION Fieldbus or PROFIBUS PA Protocols only
    N1ATEX Type n Certification and Dust
    K8ATEX Flame-proof, Intrinsic Safety, Type n, Dust (combination of E8, I1 and N1)
    E4(18)TIIS Flameproof
    E5FM Explosion-proof, Dust Ignition-proof
    I5(19)FM Intrinsically Safe, Nonincendive
    IEFM FISCO Intrinsically Safe; for FOUNDATION Fieldbus or PROFIBUS PA Protocols only
    K5FM Explosion-proof, Dust Ignition-proof, Intrinsically Safe, and Division 2
    C6CSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, and Division 2
    E6CSA Explosion-proof, Dust Ignition-proof, Division 2
    I6(13)CSA Intrinsic Safety
    K6CSA and ATEX Explosion-proof, Intrinsically Safe, and Division 2 (combination of C6, E8, and I1)
    E7IECEx Flameproof, Dust Ignition-proof
    I7IECEx Intrinsic Safety
    N7IECEx Type n Certification
    K7IECEx Flameproof, Dust Ignition-proof, Intrinsic Safety, and Type n (combination of I7, N7, and E7)
    E2INMETRO Flameproof
    I2INMETRO Intrinsic Safety
    IBINMETRO FISCO intrinsically safe; for FOUNDATION Fieldbus or PROFIBUS PA Protocols only
    K2INMETRO Flameproof, Intrinsic Safety
    E3China Flameproof
    I3China Intrinsic Safety
    N3China Type n
    EMTechnical Regulations Customs Union (EAC) Flameproof
    IMTechnical Regulations Customs Union (EAC) Intrinsic Safety
    KMTechnical Regulations Customs Union (EAC) Flameproof and Intrinsic Safety
    KBFM and CSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, and Division 2 (combination of K5 and C6)
    KDFM, CSA, and ATEX Explosion-proof, Intrinsically Safe (combination of K5, C6, I1, and E8)
    EP(20)Republic of Korea Flameproof
    IP(21)Republic of Korea Intrinsic Safety
    KP(22)Republic of Korea Flameproof, Intrinsic Safety
    Drinking water approval(23)
    DWNSF drinking water approval
    Shipboard approvals(10)
    SBSAmerican Bureau of Shipping
    SBV(24)Bureau Veritas (BV)
    SDNDet Norske Veritas
    SLL(24)Lloyds Register (LR)
    Custody transfer
    C5Measurement Canada Accuracy Approval (limited availability depending on transmitter type and range. Contact an Emerson representative.)
    Calibration certification
    Q4Calibration certificate
    QGCalibration certificate and GOST verification certificate
    QPCalibration certification and tamper evident seal
    Material traceability certification
    Q8Material traceability certification per EN 10204 3.1
    Quality certification for safety(25)
    QSPrior-use certificate of FMEDA Data
    QTSafety certified to IEC 61508 with certificate of FMEDA
    Configuration buttons
    D4(25)Analog zero and span
    DZ(26)Digital zero trim
    Display and interface options
    M4(27)LCD display with LOI
    M5LCD display
    Wireless stainless steel sensor module(13)
    WSMWireless SST sensor module
    Conduit plug(10)(28)
    DO316 SST conduit plug
    Transient terminal block(10)(29)
    T1Transient protection terminal block
    Software configuration(26)
    C1Custom Software Configuration (For wired, see the Rosemount 3051 Configuration Data Sheet. For wireless, see the Rosemount 3051 Wireless Configuration Data Sheet.)
    Low power output
    C20.8–3.2 Vdc output with digital signal based on HART Protocol (available with output code M only)
    Alarm levels(25)
    C4(30)Analog output levels compliant with NAMUR recommendation NE 43, alarm high
    CN(30)Analog output levels compliant with NAMUR recommendation NE 43, low alarm
    CRCustom alarm and saturation signal levels, high alarm (requires C1 and Rosemount 3051 Configuration Data Sheet)
    CSCustom alarm and saturation signal levels, low alarm (requires C1 and Rosemount 3051 Configuration Data Sheet)
    CTRosemount standard low alarm
    Pressure testing
    P1Hydrostatic testing with certificate
    Cleaning process area(31)
    P2Cleaning for special service
    P3Cleaning for <1 ppm chlorine/fluorine
    Ground screw(10)(32)
    V5External ground screw assembly
    Surface finish
    Q16Surface finish certification for sanitary remote seals
    Toolkit total system performance reports
    QZRemote seal system performance calculation report
    Conduit electrical connector(10)
    GEM12, 4-pin, male connector (eurofast)
    GMA size mini, 4-pin, male connector (minifast)
    NACE certificate(33)
    Q15Certificate of Compliance to NACE MR0175/ISO15156 for wetted materials
    Q25Certificate of Compliance to NACE MR0103 for wetted materials
    Cold temperature(34)
    BR5(35)–58 °F (–50 °C) cold temperature
    BR6(36)–76 °F (–60 °C) cold temperature
    HART Revision configuration (requires HART output code A)(4)
    HR5Configured for HART Revision 5
    HR7Configured for HART Revision 7
    Typical model number: 3051TG5F2A21AB4


    Good Service in WTL:
    > We offer high quality, fast delivery, competitive price for Mitsubishi Servo Motor and Servo Drive.
    > Please send your RFQ to get the latest price.
    > Normally, we will ship the items in 1-2 weeks after receive the payment.
    > We can ship to you by UPS/DHL//EMS/Fedex. Please contact us and we will use your preferred ways.
    > We have a large stock and the prices are variable, so sometimes the prices we post are not accurate.

    If needed, please contact us for specific prices.


    OUR MAIN BRAND:

    Quality 3051TG5F2A21AB4 Rosemount 3051t Pressure Transmitter In Line New In Box for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Wisdomlong Technology CO.,LTD
    *Subject:
    *Message:
    Characters Remaining: (0/3000)