Sign In | Join Free | My burrillandco.com
Home > Pressure Temperature Transmitter >

5408A1SHA1E51R3ABCAB3M5DA1 Pressure Temperature Transmitter Level Transmitter

Wisdomlong Technology CO.,LTD
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap 5408A1SHA1E51R3ABCAB3M5DA1 Pressure Temperature Transmitter Level Transmitter from wholesalers
     
    Buy cheap 5408A1SHA1E51R3ABCAB3M5DA1 Pressure Temperature Transmitter Level Transmitter from wholesalers
    • Buy cheap 5408A1SHA1E51R3ABCAB3M5DA1 Pressure Temperature Transmitter Level Transmitter from wholesalers
    • Buy cheap 5408A1SHA1E51R3ABCAB3M5DA1 Pressure Temperature Transmitter Level Transmitter from wholesalers

    5408A1SHA1E51R3ABCAB3M5DA1 Pressure Temperature Transmitter Level Transmitter

    Ask Lasest Price
    Brand Name : ROSEMOUNT
    Model Number : 5408A1SHA1E51R3ABCAB3M5DA1
    Price : Negotiate
    Payment Terms : T/T,PAYONEER
    Supply Ability : 10EA
    Delivery Time : 10-12weeks
    Certification : Does not supply
    • Product Details
    • Company Profile

    5408A1SHA1E51R3ABCAB3M5DA1 Pressure Temperature Transmitter Level Transmitter

    5408A1SHA1E51R3ABCAB3M5DA1 Level Transmitter Rosemount 5408 HART Revision 7


    Product Information Of : 5408A1SHA1E51R3ABCAB3M5DA1

    BrandEMERSON ROSEMOUNT
    Model5408A1SHA1E51R3ABCAB3M5DA1
    SUPPLY

    4–20 mA

    SIZEDoes not supply
    WeightDoes not supply

    The Rosemount 5408 is a two-wire non-contacting radar transmitter for level measurements over a broad range of liquids and slurries. It uses a unique energy efficient radar technology based on the FMCW principle to ensure reliable performance even in challenging conditions.

    (1)G½ thread form is not available with hazardous locations approvals.
    (2)Only available with 4-20 mA HART protocol.
    (3)Type A flat face for EN 1092-1 flanges.
    (4)Type B1 raised face for EN 1092-1 flanges.
    (5)Pressure limit is derated for process temperatures above 100 °F (38 °C), see Figure 6 for details.
    (6)Option code PC1 is for cone antennas only, and requires matching flange and antenna sizes. Note that all parabolic antennas come with an integrated air purge connection.
    (7)A minimum gasket thickness of 0.125 in. (3.2 mm) is required for flanges with protective plate design.
    (8)Only available with parabolic antenna and 4-in. (DN100) cone antenna.


    More options :

    3051CG1A02A1AB1H2L4M5

    3051CG5A02A1AB3H2L4M5

    3051CG1A02A1AB1H2L4M5K5

    3051CG2A02A1AB1H2L4M5K5

    3051CG5A02A1AB1H2L4M5

    3051CG4A02A1AB3H2L4M5

    3051CG2A02A1AB1H2L4M5

    3051CG3A02A1AB1H2L4M5

    3051CG4A02A1AB1H2L4M5

    3051CG1A02A1AB3H2L4M5

    3051CG2A02A1AB3H2L4M5

    3051CG3A02A1AB3H2L4M5


    MR-J2S-60B-S041U638

    MR-J2S-60B-S134

    MR-J2S-60B-S030

    MR-J2S-40B-PY096T018

    MR-J2S-40B-PY135

    MR-J2S-40B1-EH018

    MR-J2S-40B1-QA112

    MR-J2S-40CP1

    MR-J2S-20CP1

    MR-J2S-10CP1

    MR-J2S-40B-QT0009U625

    MR-J2S-40A-S004

    MR-J2S-10A1-S017

    MR-J2S-20A-S011

    MR-J2S-40A-S011

    MR-J2S-70A-S011

    MR-J2S-100A-S011

    MR-J2S-200A-S011

    MR-J2S-10A-S075

    MR-J2S-70CP-S186


    Rosemount 5408 Level Transmitter Information:

    ModelProduct Description
    5408Radar Level Transmitter
    Profile
    AStandard Monitoring & Control Applications
    Measurement type
    1Liquid Level Measurement
    3Solids Level Measurement
    4Liquid & Solids Level Measurement
    Performance class
    SStandard
    Signal output
    H4–20 mA with digital signal based on HART® Revision 6 protocol (HART Revision 7 available as option)
    FFOUNDATION™ Fieldbus
    Housing material
    AAluminum
    SStainless Steel (SST)
    Conduit/cable threads
    1½-14 NPT
    2M20 x 1.5
    3(1)
    Hazardous locations certifications
    NANone
    E1ATEX Flameproof
    I1ATEX Intrinsic Safety
    N1ATEX Type n
    IAATEX FISCO Intrinsic Safety
    E5USA Explosion-proof, Dust Ignition-proof
    I5USA Intrinsically Safe; Nonincendive
    IEUSA FISCO Intrinsic Safety
    E6Canadian Explosion-proof, Dust Ignition-proof
    I6Canadian Intrinsically Safe; Nonincendive
    IFCanadian FISCO Intrinsic Safety
    E7IECEx Flameproof, Dust Ignition-proof
    I7IECEx Intrinsic Safety
    N7IECEx Type n
    IGIECEx FISCO Intrinsic Safety
    E2(2)INMETRO Flameproof
    I2(2)INMETRO Intrinsic Safety
    N2(2)INMETRO Type n
    E3(2)China Flameproof
    I3(2)China Intrinsic Safety
    N3(2)China Type n
    E4(2)Japan Flameproof
    EP(2)Republic of Korea Flameproof
    IP(2)Republic of Korea Intrinsic Safety
    EM(2)Technical Regulations Customs Union (EAC) Flameproof
    IM(2)Technical Regulations Customs Union (EAC) Intrinsic Safety
    NM(2)Technical Regulations Customs Union (EAC) Type n
    Materials of constructionAvailable antenna types
    1316/316L/EN 1.4404Cone, Parabolic
    7All PTFE Wetted PartsProcess Seal
    2Alloy C-276 (UNS N10276) with Protective PlateCone
    3Alloy 400 (UNS N04400) with Protective PlateCone
    HAlloy C-276 (UNS N10276) Process Connection, Flange, and AntennaCone
    MAlloy 400 (UNS N04400) Process Connection, Flange, and AntennaCone
    Process connection type (see Table 3, Table 4, Table 5, and Table 6)Available antenna types
    F(3)Flat Face FlangeCone, Parabolic
    R(4)Raised Face FlangeAll
    NNPT ThreadCone
    GBSPP (G) ThreadCone, Parabolic
    BBracket MountingCone
    CTri-Clamp®Process Seal
    WWelded ConnectionParabolic
    TRing Type Joint (RTJ) FlangeCone
    Process connection size (see Table 3, Table 4, Table 5, and Table 6)Available antenna types
    A1½-in.Cone
    22-in./DN50/50ACone, Process Seal
    33-in./DN80/80ACone, Process Seal
    B3½-in.Parabolic
    44-in./DN100/100ACone, Process Seal
    66-in./DN150/150ACone
    88-in./DN200/200ACone, Parabolic
    T10-in./DN250/250AParabolic
    ZNone (use when ordering bracket mounting)Cone
    Process connection rating (see Table 3, Table 4, Table 5, and Table 6)
    ZZFor use with non-flange process connection type
    ASME flanges
    AAASME B16.5 Class 150
    ABASME B16.5 Class 300
    ACASME B16.5 Class 600
    EN flangesNote
    DKEN1092-1 PN6
    DAEN1092-1 PN16PN10 and PN16 dimensions are identical for DN50 to DN150
    DBEN1092-1 PN40PN25 and PN40 dimensions are identical for DN50 to DN150
    DCEN1092-1 PN63
    DDEN1092-1 PN100
    JIS flanges
    JKJIS 5K
    JAJIS 10K
    JBJIS 20K
    Antenna type(5)Operating pressureOperating temperature
    CAACone Antenna (PTFE seal)-15 to 363 psig (-1 to 25 bar)-76 to 392 °F (-60 to 200 °C)
    CABCone Antenna (PTFE seal)-15 to 725 psig (-1 to 50 bar)(6)-40 to 302 °F (-40 to 150 °C)
    CACCone Antenna (PTFE seal)-15 to 1450 psig (-1 to 100 bar)-40 to 212 °F (-40 to 100 °C)
    CADCone Antenna (PTFE seal)-15 to 44 psig (-1 to 3 bar)-76 to 482 °F (-60 to 250 °C)

    CBFCone Antenna (PEEK seal, FVMQ)-15 to 754 psig (-1 to 52 bar)-76 to 338 °F (-60 to 170 °C)
    CBKCone Antenna (PEEK seal, Kalrez® 6375)-15 to 754 psig (-1 to 52 bar)5 to 482 °F (-15 to 250 °C)
    CBMCone Antenna (PEEK seal, FKM)-15 to 754 psig (-1 to 52 bar)-13 to 428 °F (-25 to 220 °C)
    CBVCone Antenna (PEEK seal, Viton®)-15 to 754 psig (-1 to 52 bar)-22 to 392 °F (-30 to 200 °C)
    SAAProcess Seal Antenna-7 to 363 psig (-0.5 to 25 bar)(7)-76 to 392 °F (-60 to 200 °C)(7)
    PASParabolic Antenna, Swivel Mount-7 to 43 psig (-0.5 to 3 bar)-67 to 392 °F (-55 to 200 °C)
    Antenna sizeAvailable antenna types
    22-in. (DN50)Cone, Process Seal
    33-in. (DN80)Cone, Process Seal
    44-in. (DN100)Cone, Process Seal
    88-in. (DN200)Parabolic
    Options (include with selected model number)
    Antenna extensions (see Figure 22)Total length
    S1Extended Cone Antenna23.6-in. (600 mm)
    S2Extended Cone Antenna, Segmented47.2-in. (1200 mm)
    Purging connection (see Figure 12)(8)(9)
    PC1Purging Connector (Purge Ring)
    Display
    M5LCD Display
    Diagnostic functionality (see Smart Diagnostics Suite)
    DA1HART Smart Diagnostics Suite
    D01FOUNDATION Fieldbus Smart Diagnostics Suite
    HART revision configuration
    HR74-20 mA with digital signal based on HART Revision 7 protocol
    Open air applications configuration(10)
    OAOpen Air Applications Configuration; LPR (Level Probing Radar)
    Factory configuration
    C1Factory Configuration per Configuration Data Sheet
    Alarm limits
    C4NAMUR Alarm and Saturation Levels, High Alarm
    C5NAMUR Alarm and Saturation Levels, Low Alarm
    C8(11)Standard Rosemount Alarm and Saturation Levels, Low Alarm
    Welding standard for flanges(12)(13)
    AWAccording to ASME IX
    EWAccording to EN-ISO
    Country certification(14)
    J1Canadian Registration (CRN)
    Special quality assurance
    Q4Calibration Data Certificate
    QGCalibration Certificate and GOST Verification Certificate (only for end-destination country Russia)
    Hydrostatic testing(15)
    Q5Hydrostatic Testing, including certificate
    Material traceability certification(16)
    Q8Material Traceability Certification per EN 10204 3.1 (2.1 for non-metallic)
    Hygienic certification(17)
    QACertificate of compliance to 3-A®
    Food and Drug Administration (FDA) statement(17)(18)
    QHCertificate of Compliance to FDA
    Materials certification(19)
    Q15NACE® Material Recommendation per NACE MR0175/ISO 15156
    Q25NACE Material Recommendation per NACE MR0103/ISO 17945
    Q35NACE Material Recommendation per NACE MR0175/ISO 15156 and NACE MR0103/ISO 17945
    Welding procedure qualification record documentation(12)
    Q66Welding Procedure Qualification Record (WPQR)
    Q67Welder Performance Qualification (WPQ)
    Q68Welding Procedure Specification (WPS)
    Q79WPQR/WPQ/WPS
    Dye penetration test certificate(12)
    Q73Certificate of Liquid Penetrant Inspection
    Positive material identification certificate
    Q76Positive Material Identification Certificate of Conformance
    Overfill prevention(2)
    U1Overfill Prevention According to WHG/TUV
    Shipboard approvals(2)(20)
    SBSAmerican Bureau of Shipping Type Approval
    SDNDet Norske Veritas Germanischer Lloyd (DNV GL) Type Approval
    SLLLloyd's Register Type Approval
    SBVBureau Veritas Type Approval
    Extended product warranty(21)
    WR33-year Limited Warranty
    WR55-year Limited Warranty
    Conduit electrical connector (shipped uninstalled)(22)
    ECM 12, 4-pin, Male connector (eurofast®)
    MCA size Mini, 4-pin, Male connector (minifast®)
    Specials (see Engineered solutions)
    PXXXXCustom Engineered Solutions beyond standard model codes. Consult factory for details.
    Typical model number: 5408 A 1 S H A 1 E5 1 R 3 AB CAB 3 M5 DA1


    Good Service in WTL:
    > We offer high quality, fast delivery, competitive price for Mitsubishi Servo Motor and Servo Drive.
    > Please send your RFQ to get the latest price.
    > Normally, we will ship the items in 1-2 weeks after receive the payment.
    > We can ship to you by UPS/DHL//EMS/Fedex. Please contact us and we will use your preferred ways.
    > We have a large stock and the prices are variable, so sometimes the prices we post are not accurate.

    If needed, please contact us for specific prices.


    OUR MAIN BRAND:

    Quality 5408A1SHA1E51R3ABCAB3M5DA1 Pressure Temperature Transmitter Level Transmitter for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Wisdomlong Technology CO.,LTD
    *Subject:
    *Message:
    Characters Remaining: (0/3000)